EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
High-Availability (HA)
This section describes the SNMP trap events concerned with the High-Availability (HA) system.
Redundant Board Trap
Table 7-64: acRedundantBoardAlarm
Event acRedundantBoardAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.97
Description The notification trap is sent by the active device when an alarm or
notification is sent by the redundant device:
System (1)
acBoardFatalError
acBoardTemperatureAlarm
ethernetLink (4)
acBoardEthernetLinkAlarm
chassis (16)
fanTray (17)
acFanTrayAlarm
powerSupply (18)
acPowerSupplyAlarm
module (21)
acHwFailureAlarm
analogports (24)
acAnalogPortSPIOutOfService
acAnalogPortHighTemperature
acAnalogPortGroundFaultOutOfService
trunk (25)
EthGroup (37)
acEthernetGroupAlarm
Default
Severity
Indeterminate
Event Type Other (0)
- 165 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing