CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acEthernetGroupAlarm
up again.
LDAP Lost Connection Alarm
Table 7-39: acLDAPLostConnection
Alarm acLDAPLostConnection
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.75
Default Severity Minor
Event Type communicationsAlarm
Probable Cause communicationsSubsystemFailure
If a connection is idle for more than the maximum configured
time in seconds that the client can be idle before the LDAP server
closes the connection, the LDAP server returns an LDAP
disconnect notification and this alarm is sent.
Alarm Text LDAP Lost Connection
Status Changes The alarm is sent when there is no connection to the LDAP server
OCSP Server Status Alarm
Table 7-40: acOCSPServerStatusAlarm
Alarm acOCSPServerStatusAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.78
Default Severity Major / Clear
Event Type communicationsAlarm
Probable Cause communicationsSubsystemFailure
Alarm Text OCSP server alarm
Corrective Action Try any of the following:
Repair the Online Certificate Status Protocol (OCSP) server
Correct the network configuration
- 144 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals