CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acActiveAlarmTableOverflow
Event Type processingErrorAlarm
Probable
Cause
resourceAtOrNearingCapacity (43)
Alarm
Severity
Condition Text Corrective Action
Major Too
many
alarms to
fit in the
active
alarm
table
"Active
alarm
table
overflow"
Some alarm information may be lost but the
ability of the device to perform its basic
operations is not impacted.
A reboot is the only way to completely clear
a problem with the active alarm table.
Contact AudioCodes Support.
Remains
'Major'
until
reboot. A
'Clear' trap
is not sent.
After the
alarm is
sent
- Note that the status remains 'Major' until reboot
as it denotes a possible loss of information until
the next reboot. If an alarm is sent when the
table is full, it is possible that the alarm is active,
but does not appear in the active alarm table.
Analog Port Alarms
These alarms are applicable only to analog interfaces.
Analog Port SPI Out-of-Service Alarm
The alarm is applicable only to analog interfaces.
Table 7-46: acAnalogPortSPIOutOfService
Alarm acAnalogPortSPIOutOfService
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.46
Default
Severity
Major
Source
Varbind
System#0/analogports#<n>, where n is the port number
- 149 -