CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acBoardControllerFailureAlarm
Default
Severity
Major
Event Type processingErrorAlarm
Probable
Cause
softwareError (46)
Severity Condition Text Additional Information
Major Failure in a Proxy Set "Proxy Set ID n"
Where n represents
the Proxy Set ID.
Proxy has not been
found or registration
failure
"Proxy not found. Use
internal routing"
-OR-
"Proxy lost. Looking for
another Proxy"
Check the network
layer
Make sure that the
proxy IP and port
are configured
correctly.
Connection to Proxy is
down
"BusyOut Trunk/Line n
Connectivity Proxy
failure"
-
Connection to the
Proxy Set associated
with the trunk or line is
down
"BusyOut Trunk/Line n
Proxy Set Failure"
Where n represents
the BRI / PRI trunk or
FXO line.
-
Failure in TDM-over-IP
call
"BusyOut Trunk n TDM
over IP failure (Active
calls x Min y)"
Where n represents
the the BRI / PRI
trunk.
-
Failure in server
registration for the
trunk/line
"BusyOut Trunk/Line n
Registration Failure"
Where n represents
the BRI / PRI trunk or
FXO line.
-
- 122 -