CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acBoardControllerFailureAlarm
Default
Severity
Major
Event Type processingErrorAlarm
Probable
Cause
softwareError (46)
Severity Condition Text Additional Information
Major Failure in a Proxy Set "Proxy Set ID n"
Where n represents
the Proxy Set ID.
Proxy has not been
found or registration
failure
"Proxy not found. Use
internal routing"
-OR-
"Proxy lost. Looking for
another Proxy"
Check the network
layer
Make sure that the
proxy IP and port
are configured
correctly.
Connection to Proxy is
down
"BusyOut Trunk/Line n
Connectivity Proxy
failure"
-
Connection to the
Proxy Set associated
with the trunk or line is
down
"BusyOut Trunk/Line n
Proxy Set Failure"
Where n represents
the BRI / PRI trunk or
FXO line.
-
Failure in TDM-over-IP
call
"BusyOut Trunk n TDM
over IP failure (Active
calls x Min y)"
Where n represents
the the BRI / PRI
trunk.
-
Failure in server
registration for the
trunk/line
"BusyOut Trunk/Line n
Registration Failure"
Where n represents
the BRI / PRI trunk or
FXO line.
-
- 122 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals