EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #129 background imageLoading...
Page #129 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acProxyConnectionLost
Major Connection to the Proxy Set
is lost and this Proxy Set is
configured with fallback to
routing table (IsFallbackUsed
parameter).
Note: Applicable only to the
Gateway application.
"Proxy Set <ID>:
Proxy not
found. Use
internal
routing"
1. Ping the proxy
server. If there is no
ping, contact your
proxy provider. The
probable reason is
the proxy is down.
2. Ping between the
proxy and Audi-
oCodes device. If
there is no ping, the
problem could be a
network/router
issue.
3. If you have more
than one device
connected to this
same proxy, check
if there are more
AudioCodes devices
with the same
alarm. If this is the
case, this could con-
firm that this is not
AudioCodes device
issue.
4. Check that routing
using the device's
routing table is func-
tioning correctly.
5. Contact Audi-
oCodes support
and send a syslog
and network cap-
ture for this issue.
Minor All proxy servers were online
and now at least one proxy
server in the Proxy Set is
offline (and at least one
proxy server is still online)
"Proxy Set <ID>
("<Name>"):
Server <IP
address>:<port>
is down - one or
more servers in
- 120 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing