CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acProxyConnectionLost
Severity Condition Text Corrective Action
Major Connection to all the proxy
servers in the Proxy Set are
lost (offline) and the 'Proxy
Load Balancing Method'
parameter is disabled.
"Proxy Set
<ID>: Proxy
lost. looking for
another proxy"
1. Ping the proxy
server. If there is no
ping, contact your
proxy provider. The
probable reason is
the proxy is down.
2. Ping between the
proxy and Audi-
oCodes device. If
there is no ping, the
problem could be a
network/router
issue.
3. If you have more
than one device
connected to this
same proxy, check
if there are more
AudioCodes devices
with the same
alarm. If this is the
case, this could con-
firm that this is not
AudioCodes device
issue.
4. Check if routing via
the redundant
proxy is operating
correctly. If it is,
then this could
mean that it's not a
network issue.
5. Contact Audi-
oCodes support
center and send a
syslog and network
capture for this
issue.
The number of online proxy
servers in the Proxy Set is
less than the number
configured for the 'Min.
Active Servers for Load
Balancing' parameter and
the 'Proxy Load Balancing
Method' parameter is
enabled (Round Robin or
Random Weights).
"Proxy Set <ID>:
Proxy lost.
looking for
another proxy"
- 119 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals