CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acLicensePoolInfraAlarm
Text
Event Type communicationsAlarm
Probable Cause keyExpired
Alarm Severity Condition Text Corrective Action
Critical Device unable to establish
an HTTPS REST connection
with OVOC after successive
attempts.
"License Pool
Alarm. License
pool validity is
about to
expire."
In OVOC, perform
the 'MG Update'
action to re-
establish a REST
connection with
device and to send
the latest license.
The device's license has
expired.
"License Pool
Alarm. The
device license
has expired!
Use of this
device is strictly
prohibited."
Major The last attempt to
establish an HTTPS REST
connection with OVOC was
not successful.
"License Pool
Alarm. Device
was unable to
access the
License
Server."
Wait for the
next
connection
attempt.
In OVOC,
perform the
'MG Update'
action to re-
establish a
REST
connection
with device and
to send the
current license.
The device has been
configured as Non-
Managed in the OVOC
License Pool. If there are
active licensed sessions for
this device, the device
automatically performs a
"License Pool
Alarm. Device is
no longer
managed by
the SBC License
Pool."
If you wish,
reconfigure the
device to be
managed by the
OVOC License
Pool.
- 134 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C