CHAPTER4 Topology MIB Objects
Mediant 800 SBC | SNMP Reference Guide
ifTable & ifXTable Value
standard. Support for 'testing' is not required.
ifOperStatus Up or Down corresponding to acAnalogFxsFxoType where
Unknown is equal to Down.
ifLastChange The value of sysUpTime at the time the interface entered its
current operational state.
ifInOctets The number of octets in valid MAC frames received on this
interface, including the MAC header and FCS. This does
include the number of octets in valid MAC Control frames
received on this interface.
ifInUcastPkts As defined in IfMIB.
ifInDiscards As defined in IfMIB.
ifInErrors The sum for this interface of dot3StatsAlignmentErrors,
dot3StatsFCSErrors, dot3StatsFrameTooLongs, and
dot3StatsInternalMacReceiveErrors.
ifInUnknownProtos As defined in IfMIB.
ifOutOctets The number of octets transmitted in valid MAC frames on
this interface, including the MAC header and FCS. This
does include the number of octets in valid MAC Control
frames transmitted on this interface.
ifOutUcastPkts As defined in IfMIB.
ifOutDiscards As defined in IfMIB.
ifOutErrors The sum for this interface of: dot3StatsSQETestErrors,
dot3StatsLateCollisions, dot3StatsExcessiveCollisions,
dot3StatsInternalMacTransmitErrors and
dot3StatsCarrierSenseErrors.
ifName Ethernet port #1 or# 2
ifInMulticastPkts As defined in IfMIB.
ifInBroadcastPkts As defined in IfMIB.
ifOutMulticastPkts As defined in IfMIB.
ifOutBroadcastPkts As defined in IfMIB.
- 22 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing