CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acCloudLicenseManagerAlarm
Text
Event Type processingErrorAlarm
Probable
Cause
configurationOrCustomisationError
Severity Condition Text Corrective Action
Major There is no connection
between the device and
OVOC either prior to initial
handshake or due to long
disconnection time (default
is 3 months, but it can be
overridden by OVOC)
"No
connection
with OVOC"
Check TCP/TLS
connectivity.
Check that device is
registered with OVOC.
The device did not send
usage reports to OVOC for a
specified number of days.
"Failed to
send usage
report to
OVOC for X
days."
Check TCP/TLS
connectivity.
The Fixed License Pool is
enabled and an attempt was
made to enable the Floating
License or Flex License.
"Floating
license
cannot be
enabled
when device
is managed
by License
Pool."
Disable the Floating
License or Flex License on
the device.
Remove the device from
the Fixed License Pool in
OVOC.
Critical The device couldnt connect
to OVOC (handshake).
"Connection
with OVOC
failed,
response
code <XXX>"
<Forbidden 403>:
Contact AudioCodes
support.
<unauthorized 401>:
Check username and
password.
Possible HTTP response
codes and reasons:
4xx-6xx responses: The
device retries the
request using the value
- 137 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals