name of the SNMPv3 that this user is associated with.
2. If a row does not already exist for this combination of user and SecurityLevel, add a row to
the snmpTargetParamsTable with these values: Name=usm<user>, MPModel=3(SNMPv3),
SecurityModel=3 (usm), SecurityName=<user>, SecurityLevel=M, where M is either 1
(noAuthNoPriv), 2(authNoPriv) or 3(authPriv).
All changes to the trap destination configuration take effect immediately.
To delete a trap destination:
Remove the appropriate row from the snmpTargetAddrTable.
If this is the last trap destination associated with this user and security level, you could
also delete the appropriate row from the snmpTargetParamsTable.
To modify a trap destination:
You can change the IP address and or port number for an existing trap destination. The same
effect can be achieved by removing a row and adding a new row.
Modify the IP address and/or port number for the appropriate row in the
snmpTargetAddrTable.
To disable a trap destination:
Change TagList on the appropriate row in the snmpTargetAddrTable to the empty string.
To enable a trap destination:
Change TagList on the appropriate row in the snmpTargetAddrTable to AC_TRAP.
Change TagList on the appropriate row in the snmpTargetAddrTable to "AC_TRAP".
- 19 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals