CHAPTER6 Performance Monitoring
Mediant 800 SBC | SNMP Reference Guide
Performance Monitoring
MIB
G/
C
Int
Va
l
Mi
n
M
ax
Av
g
Tb
LT
Tb
T
Ta
HT
HT LT
(configured by the
BrokenConnectionEventT
imeout parameter).
MIB Name: acPMSBCSRDInShortCallsTable
OID: 1.3.6.1.4.1.5003.10.8.2.54.152.3
Source Name: PM_gwSBCSRDInShortCalls
Indicates the number of
incoming calls per SRD,
whose duration was less
than the value configured
by the ShortCallSeconds
parameter.
C 15
ü û û û û û û û û
MIB Name: acPMSBCSRDOutShortCallsTable
OID: 1.3.6.1.4.1.5003.10.8.2.54.152.4
Source Name: PM_gwSBCSRDOutShortCalls
Indicates the number of
outgoing calls per SRD,
whose duration was less
than the value configured
by the ShortCallSeconds
parameter.
C 15
ü û û û û û û û û
MIB Name: acPMSBCSRDInAttemptedRegistrationsTable
OID: 1.3.6.1.4.1.5003.10.8.2.54.153.3
Source Name: PM_gwSBCSRDInAttemptedRegistrations
Indicates the number of
incoming attempted user
registrations per SRD.
C 15
ü û û û û û û û û
MIB Name: acPMSBCSRDOutAttemptedRegistrationsTable
OID: 1.3.6.1.4.1.5003.10.8.2.54.153.4
Source Name: PM_gwSBCSRDOutAttemptedRegistrations
Indicates the number of
outgoing attempted user
C 15
ü û û û û û û û û
- 77 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing