Version 5.8 143 September 2009
SIP User's Manual 3. Web-Based Management
¾ To configure the Authentication Table:
1. Set the 'Authentication Mode' parameter to 'Per Endpoint' (refer to ''Configuring Proxy
and Registration Parameters'' on page 94).
2. Open the 'Authentication' page (Configuration tab > Protocol Configuration menu >
Endpoint Settings submenu > Authentication page item).
Figure 3-82: Authentication Page
3. In the 'User Name' and 'Password' fields corresponding to a port, enter the user name
and password respectively.
4. Click the Submit button to save your changes.
5. To save the changes to flash memory, refer to ''Saving Configuration'' on page 167.
3.3.4.9.2 Configuring Automatic Dialing
The 'Automatic Dialing' page allows you to define a telephone number that is automatically
dialed when an FXS or FXO port is used (e.g., off-hooked).
Notes:
After a ring signal is detected on an 'Enabled' FXO port, the device
initiates a call to the destination number without seizing the line. The line
is seized only after the call is answered.
After a ring signal is detected on a 'Disabled' or 'Hotline' FXO port, the
device seizes the line.
You can also configure automatic dialing using the ini file table parameter
TargetOfChannel.
You can configure the device to play a Busy/Reorder tone to the Tel side
upon receiving a SIP 4xx, 5xx, or 6xx response from the IP side (i.e., Tel-
to-IP call failure), using the ini file parameter FXOAutoDialPlayBusyTone
(refer to ''SIP Configuration Parameters'' on page 252).

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet

Related product manuals