Parameter Description
Web: V.21 Modem Transport Type
EMS: V21 Transport
[V21ModemTransportType]
V.21 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent) -- default
[1] Enable Relay = N/A
[2] Enable Bypass.
[3] Events Only = Transparent with Events.
Web: V.22 Modem Transport Type
EMS: V22 Transport
[V22ModemTransportType]
V.22 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent)
[1] Enable Relay = N/A
[2] Enable Bypass = (default)
[3] Events Only = Transparent with Events
Web: V.23 Modem Transport Type
EMS: V23 Transport
[V23ModemTransportType]
V.23 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent)
[1] Enable Relay = N/A
[2] Enable Bypass = (default)
[3] Events Only = Transparent with Events
Web: V.32 Modem Transport Type
EMS: V32 Transport
[V32ModemTransportType]
V.32 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent)
[1] Enable Relay = N/A
[2] Enable Bypass = (default)
[3] Events Only = Transparent with Events
Note: This parameter applies only to V.32 and V.32bis
modems.
Web: V.34 Modem Transport Type
EMS: V34 Transport
[V34ModemTransportType]
V.90 / V.34 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent)
[1] Enable Relay = N/A
[2] Enable Bypass = (default)
[3] Events Only = Transparent with Events
EMS: Bell Transport Type
[BellModemTransportType]
Determines the Bell modem transport method.
[0] = Transparent (default).
[2] = Bypass.
[3] = Transparent with events.

Table of Contents

Other manuals for AudioCodes MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MP-124 and is the answer not in the manual?

AudioCodes MP-124 Specifications

General IconGeneral
ModelMP-124
CategoryGateway
Analog Ports24 FXS
Ethernet Ports2
Protocol SupportSIP, H.323
Fax SupportT.38, G.711 pass-through
Power Supply100-240VAC, 50-60Hz
Operating Temperature0°C to 40°C
Voice CodecsG.711, G.729, G.723.1, G.726
ManagementSNMP
Storage Temperature-20°C to 70°C
Humidity10% to 90%, non-condensing
Network Interface10/100Base-T Ethernet