DL205 User Manual, 4th Edition, Rev. D
5-255
Chapter 5: Standard RLL Instructions
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
B
C
D
Move Double Word (MOVED) (IB-201)
Move Double Word moves (copies) a double word to two consecutive memory locations
directly or indirectly via a pointer, either as a double HEX constant, from a double memory
location, or indirectly through a pointer to a double memory location.
MOVED Parameters
From DWORD: specifies the double word
that will be moved to another location
To DWORD: specifies the location to which
where the “From DWORD” will be moved
MOVED Example
In the following example, the MOVED instruction is used to move 32 bits of data from V2000
and V2001 to V3000 and V3001 when C100 turns on.
Parameter DL205 Range
From DWORD ⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠V,P,K K0-FFFFFFFF; See DL205 V-memory map - Data Words
To DWORD ⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠⸠V,P See DL205 V-memory map - Data Words
DS5 Used
HPP
N/A
230
240
250-1
260