119
REFRIGERATORS
shortperiodoftime?
a) Check whether the cooling compartment
worksafter4–5hours.
q)Ambienttemperaturestoohigh.
a)Regularlyremoveventilationgrilles.
Failure:Therefrigeratordoesnotcoolingas
operationmode.
Possiblecauseandactionyoucantake
q)Gascylinderempty.
a)Changegascylinder.
q)Isthesupplyshut-offdeviceopen?
a)Opentheshut-offdevice.
q)Airinthegaspipe?
a) Switch off the appliance and start again.
Repeatthisprocedure3–4times,ifnecessary.
Failure:The refrigerator does notcool in 12v
operation.
Possible cause and action you can take
q)On-boardfusedefective.
a)Fitnewfuse.
q)On-boardbatterydischarged.
a)Checkbattery,chargeit.
q)Enginenotrunning.
a)Startengine.
q) Heating element defective (please also
refertofailureindication).
a)PleaseinformDometicCustomerServices.
Failure:Therefrigeratordoesnotcoolin230v
operation.
Possible cause and action you can take
q)On-boardfusedefective.
a)Fitnewfuse.
q)Noconnectiontosupplyvoltage.
a)Establishpowerconnection.
q) AES: gas operation despite connection to
thesupplyvoltage.
a) Appliance switches to gas operation due
to insufcient supply voltage (automatically
switchesbackto230voperation).
q) Heating element defective (please also
refertofailureindication).
a)PleaseinformDometicCustomerServices.
Maintenance
Please visit www.dometicapproved.co.uk or
telephone -44 (0) 844 626 0130 to locate
yourlocalservicecentre.Installationmayonly
be carried out by authorised personnel. We
recommendcontactingyourDometicService
Centre.
EN 1949 stipulates that the appliance’s gas
equipment and its associated fume system
must be inspected after installation and a
certicateissued.
Whenusingthefridgeforextendedperiodson
gasoperationDometicrecommendaseasonal
serviceiscarriedoutbyauthorisedpersonnel.
It is the user’s responsibility to arrange for
inspectionsafterpurchase.
It is recommended that the gas burner be
inspected and cleaned as necessary at least
onceayear.
Wealsorecommendmaintenancefollowingan
extendedshutdownofthevehicle.