72
HEATINGSYSTEMS
Desired Room Temperature
Thedesiredroomtemperaturecanbesetfrom
5°Cto30°C,in0.5increments.
i
TheWorldHealthOrganisation
recommendsaroomtemperatureof
18–24°Cforhealthyliving.
NB: If Day or Night Mode are active, the
temperaturecannotbeadjusted,andthePlus
andMinusbuttonswillbegreyedout.
•The current desired room temperature is
displayed.
•AdjustbypressingPlusorMinusbutton.
Domestic Hot Water
TheAldeboilerstores8.4Litresofhotwater
asstandard.Ifthehotwatercylinderisempty,
theairisheatedbutnodamagecanresult.
i
Inagoodsummer,forexample,lower
thedesiredtemperatureonthe
controlpaneltoaround10°C.The
centralheatingwillnotcirculate
(unlessthetemperaturedropsto
10°C),butyoucanstillcontrolhot
water.
NB:IfDayorNightModeSansHotWaterare
active,thehotwatercannotbeadjusted,and
thePlusandMinusbuttonswillbegreyedout.
•Hot Water Ignore. Volume bar empty.
No attempt is made to heat hot water
specically. This saves energy when the
freshwaterisdraineddown.
•HotWaterNormal.Volumebarhalf-full.Hot
waterisheatedtogreaterthan50°C.NB:If
circulationpumpissettoContinuous,this
optionwillnotbeavailable.
•Hot Water Boost.Volume barfull. Central
heatingcirculationisdisabledfor30mins.
Hotwaterisheatedtogreaterthan65°C.
After 30 mins the system reverts to Hot
WaterNormal.
•AdjustbypressingPlusorMinusbutton.
Electric Heating
Check that 230v supply is displayed on
the Standby Screen. The Alde boiler is
programmed to use power economically and
therearetimeswhenitmayusenopowerat
all,evenifsetto3kW.
•Select Off, 1, 2 or 3kW electric heating.
Morepowerequalsbetterperformance,but
may be restricted by the current (amps)
limitontheelectrichook-up.
•AdjustbypressingPlusorMinusbutton.
Max current draw from 230v supply is 4.5A
on1kW,9Aon2kW,14Aon3kW.Iftheelectric
supplyhasunstablevoltage,theamperagewill
alsouctuate.
Gas Heating
TheAlde boiler is programmed tousepower
economically.Thegasburnerhastwostages,
shiftingdynamicallybetweenloworfullame.
Therearetimeswhenitmayusenopowerat
all,evenifgasheatingisselected.
•Press the Flame button to select gas
heating.Greenison,blueisoff.
Use both gas and electric heating for best
performance.
Shutting Down the System
Tosaveenergy,thecontrolpanelonlyupdates
the boiler after the lastadjustmentis made.
Wait10secsbeforeshuttingdownthesystem
toensuretheboilerisupdated.
•PressthePowerbuttonagain.Thescreen
goes dark, the green LED is unlit. The
systemisoff.
Setup
MostUKinstallationsdonotneed settingup
intheSettingsMenu,andusedefaultfactory
settings.
Restore Default Factory Settings
Before using the system for the rst time,
restoredefault factorysettings. Yourcontrol
panelmayhavebeentestedbythedealeror
installer, and some settings may have been
changed.
1. Press Tool button to access the Settings
Menu(bottomrightinMainMenu).
2.Press down arrow, until Reset button is
displayed.
3.PresstheResetbuttontoproceed.
Setup Expansion Tank Pump
To use the 12v circulation pump in the
expansiontank,youmustsetitup.Thisisnot
adefaultfactorysetting.
NB: Under factory settings, the system will
usethe12vinlinecirculationpumpbydefault.
1. Press Tool button to access the Settings
Menu(bottomrightinMainMenu).
2.Press down arrow, until Circulation Pump
buttonisdisplayed.
3.Press Circulation Pump button, select
ExpansionTankPumptoproceed.