Troubleshooting
TheAlde control panelwill display any error
messages.Seethe operatingandinstallation
instructionssuppliedseparately.
The system is completely dead, the control
panel is blank
•Check the 20mm T3.15 amp glass fuse in
the boiler. This is locatedunder the lidof
theblackplasticservicehatch,inagreen
plasticfuseholder.
•Checkthe12vsupplytotheboiler,itshould
beabove12v.
•Check the 12v cable is plugged into the
boiler.Checkthecableispluggedintothe
Aldecontrolpanel.
The boiler will not ignite on gas
•Checkthegascylinderisfull.Tryadifferent
gascylinder,ensuringitispropanegas.
•The system may not need to use gas
heating,ifalsousingelectricheating.
•Theuids in the boilermayalreadybe at
operatingtemperature.
The boiler will not heat on 230v electric
•Checkthatany230visolatorswitchesare
on(theywilloftenhaveanLEDindicator).
•Checkthe230vsupplytothevehicle.
•Theuids in the boilermayalreadybe at
operatingtemperature.
No hot water
•Check that “hot water ignore” is not
activatedontheAldecontrolpanel.
•Check that constant pumping is not
activatedontheAldecontrolpanel.
•Checkforotherconictingsettingsonthe
Aldecontrolpanel.
•Check the freshwater supply and water
pump.
No central heating
•Bleedthesystemofair.
•Checktheuidlevelintheexpansiontank.
•Check that the circulation pump is
responding.
•Check that “hot water boost” is not
activatedontheAldecontrolpanel.
•Usegasandelectricheating.
•Check that vents in the furniture are not
obstructed.
•Check the condition of the heat transfer
uid.
•Most vehicles will reach a comfortable
temperaturewithinanhour,innon-extreme
conditions.
If problems persist, please contact Alde, or
yourdealerorinstaller.