78
HEATINGSYSTEMS
Heating without water temperature
monitoring.
Selectgas,electricalormixedoperationusing
the power switch. Illumination ofthe yellow
LED on the power selector switch indicates
thattheunitisoperatingwith230v.
Move rotary switch on control panel to
operatingposition.
Turn the rotary switch to the desired
thermostat setting (1–5). The greenLED for
operation is lit and simultaneously indicates
thepositionoftheselectedroomtemperature.
Theyellow(LED)willbelitonlywhenthewater
temperatureisbelow5°C.
The device automatically selects the
required power setting in accordance with
the temperature difference between the
temperatureselectedonthecontrolpaneland
thecurrentroomtemperature.Oncetheroom
temperatureselectedonthecontrolpanelhas
been reached, the heater switches off. The
warm air fan continues to run at slow speed
until the outgoing air temperature (on the
unit)hasfallento40°Corless.
If the boiler is lled, the water will
automatically be heated at the same time.
The water temperature is then dependent
on the heating output being given off and
thedurationofheatingrequiredtoreachthe
desiredroomtemperature.
Heating with drained water system.
Select gas or electrical operation using the
power selector switch. Illumination of the
yellow LED on the power selector switch
indicatesthattheunitisoperatingwith230v.
Move rotary switch on control panel to
operatingposition.
Turn the rotary switch to the desired
thermostat setting (1–5). The greenLED for
operation is lit and simultaneously indicates
thepositionoftheselectedroomtemperature.
The yellow LED will be lit only when the
temperatureoftheunitisbelow5°C.
Depending on the operating mode, the unit
will automatically select the required power
levelaccordingtothetemperaturedifference
betweenthesettingonthecontrolpaneland
thecurrentroomtemperature.Oncetheroom
temperatureselectedonthecontrolpanelhas
been reached, the heater switches off. The
warm air fan continues to run at slow speed
until the outgoing air temperature (on the
unit)hasfallento40°Corless.
Switching off
IfthegreenLEDblinksafterswitching
off,thentheunit’safter-runningis
activeinordertoreducetheunit’s
temperature.Thiswillendafterafew
minutesandthegreenLEDwillgooff.
Alwaysdrainwatercontentsifthereisarisk
offrost.
If the appliance is not to be used for a
prolongedperiod,closethequick-actingvalve
in the gas supply line and turn off the gas
cylinder.
Fault
Gas Operation
Ifafaultoccursduringgasoperationthered
LEDonthecontrolpanelilluminates.
Please consult the troubleshooting list for
possiblecauses.thiscanbefoundonpages78
and79.
Areset(faultreset)iscarriedoutbyswitching
off,waitinguntilallLEDsonthecontrolpanel
havestoppedashingandthenswitchingthe
heateronagain.
Ifawindowtowhichawindowswitch
hasbeenttedisopened,theheater
stopsoperatingandtheredLED
ashes.Theheatercontinues
operatingwhenthewindowisclosed.
Electrical Operation
Intheeventofamalfunctionontheelectrical
mode, the yellow LED on the power selector
switchgoesoffandtheredLEDonthecontrol
panelasheswith5Hz.
Possible causes can be found in the
troubleshootinglist,pages78&79.