Fault Cause Remedy
No LED is shining, the
device is switched on and
is supplied with operating
current.
Automatic restart is
blocked, e.g. after a
powerfailure.
Reset (fault reset) by switching off,
waiting5secondsandthenswitching
onagain.
After switching (winter
and summer operation)
noneoftheLEDsarelit.
Nooperatingvoltage.
Device fuse or vehicle
fusedefective.
Check12vbatteryvoltage,chargeif
necessary.
Checkallelectricalplugconnections.
Check the unit or vehicle fuse and
replaceifnecessary(seefuses).
The green LED comes on
when the unit is switched
onbuttheheaterdoesnot
operate.
Thetemperaturesetting
on the control panel is
lower than the room
temperature.
Select higher room temperature at
thecontrolpanel.
After switching on the
heating system, the green
LED shines and
a.TheredLEDasheswith
5Hz.
Openwindowabove
cowl(windowswitch).
Under-voltage.Battery
voltageistoolow<10.0v.
No230voperating
voltage.
230vfusedefective.
Overheatingprotection
hasactivated.
Closewindow.
Chargebattery.Ifnecessaryreplace
oldbattery.
Re-establish230voperational
voltage.
Replace230vfuse.
Resetoverheatingprotection.Allow
heatertocool,removeconnection
coverandpressresetbutton.
b.TheredLEDasheswith
1Hz.
Threateningunder-
voltage.Batteryvoltage
istoolow<10.4v.
Chargebattery.
c. The red and the yellow
LEDs ash alternately
with1Hz.
Thereisathreatof
under-voltagewhen
heatingupthewater.
Batteryvoltageistoo
low<10.4v.
Chargebattery.
After the heater is
switched on, the green
LEDislitandtheredLED
blinks.
Electronicsare
defective.
Please contact the Truma Service
Centre.
Approximately30seconds
after the heater is
switched on, the red LED
islit.
Gascylinderorquick-
closurevalveinthegas
lineisclosed.
Combustion air in-feed
or exhaust outlet is
sealed.
Checkgassupplyandopenvalves.
Inspectopeningsforcontamination
(slush,ice,leaves,etc)andremove
contaminationifnecessary.