7.9 Optional accessories
Functions
5284 / 08/2023 enBENNING ST 755+ / ST 760+52
Requirements
• Please observe the operating manual of the respective barcode scanner.
• The battery of the cordless barcode scanner is charged.
• The battery of the cordless barcode scanner is not in charging mode.
Procedure– Putting the USBbarcode scanner into operation
1. Switch on the device.
2. Connect the connecting cable of the barcode scanner to a USB-Aport of the device.
The statusLED of the barcode scanner lights up and an acoustic signal is emitted. The
barcode scanner is ready for operation.
Procedure– Putting the wireless barcode scanner into operation (wireless)
1. Switch on the device.
The barcode scanner must be configured to the “2.4GHz wireless transmission" operating
mode. The statusLED of the barcode scanner is off, indicating that the barcode scanner is
ready for radio transmission to the supplied USBdongle.
2. Plug the USBdongle of the barcode scanner into a USB-Aport of the device.
The barcode scanner is ready for operation.
Procedure– Putting the cordless barcode scanner into operation (cordless)
1. Switch on the device.
The barcode scanner must be configured to the “cordless” operating mode. The statusLED
of the barcode scanner changes to flashing mode and lights up in blue colour. The flashing
mode of the barcode scanner indicates that the barcode scanner is ready for cordless
connection to the device.
2. Establish a Bluetooth®connection between the device and the barcode scanner
[}page59].
The barcode scanner is ready for operation.
If the connection fails, restart the device as well as the barcode scanner and repeat the
commissioning.
To disable the barcode scanner, press and hold the button of the barcode scanner for
approx. 12seconds. Press the button again to re-enable the barcode scanner.
Procedure– Operating the barcode scanner
You can create and select test samples using the barcode scanner in the database as well as
during the test procedure (automatic and manual tests according to VDE). Instead of entering
the test sample identification number manually, the identification number or barcode is scanned
using the barcode scanner by pressing a button. The identification number will be entered
automatically.