9.3 Automatic testing
Testing
5284 / 08/2023 enBENNING ST 755+ / ST 760+76
9.3 Automatic testing
Automatic testing is primarily intended for periodic testing and tests after modification or repair
of test sample entries that have already been created.
Requirements
Please observe the requirements for measuring [}page71].
Approved safety measuring lines
Menu
Main menu> Automatic test
Procedure
1. Select a database.
If no database is available, create a new database.
2. Select a customer.
If no customer is available, create a new customer.
3. Select a department.
If no department is available, select “(display all)” or “(empty)” or create a new department.
4. Select a test sample (IDno./ Overdue devices)
To select a test sample that is overdue for testing, select a test sample using the
“Overduedevices” line.
When you have selected all the parameters stated, the "Start" button will be displayed.
5. Start the automatic test and follow the instructions.
If the connection test [}page40] is successful, the “Visual inspection” screen will be
displayed.
6. Carry out the visual inspection.
7. Evaluate the result of the visual inspection.
There are no defects:
Confirm using the button “OK” or “AllOK”.
If there are no serious defects, tap the "Start" button to complete the visual inspection
and start the test procedure.
There are defects: Evaluate the defect with the "Error" button or for each negative result
with the "F" button for ‘fail’ or “N.a." for ‘not available’.
If there are serious defects, stop the test. To do this, tap the "Done" button to go directly
to the test report.
8. Carry out the test procedure [}page31]. To do this, follow the instructions on the display
and the instructions for the respective individual test [}page79].
After the test procedure is completed, the test report is displayed in the “Testresult” screen.
9. Select the test type. To do this, scroll to the end of the test report and choose between
periodic testing, test after modification, after repair or receiving inspection in the drop-down
menu.
You can enter an additional comment in the “Note”line.
10. To complete the test procedure, select the desired option (print, discard or save) with the
“Testresult” test report.