51
BIOSYSTEMS A25
Firmware initialization
Firmware Version: A25 User V2.80
Serial Number: 831011284
FLASH functions transferred to RAM
Interrupt Vectors transferred to RAM
Interrupts enabled
Checking firmware integrity
Checking program checksum:
Checksum correct! Program Checksum=0xDF32 Size=439296
Checking A25 configuration checksum:
Checksum correct! Configuration Checksum=0x21C2 Size=250
Checking A25 configuration backup checksum:
Checksum correct! Configuration backup Checksum=0x21C2 Size=250
Loading A25 Configuration from FLASH
Configuration in FLASH is correct
Adjustments loaded:
Temperature correction for Rotor=-0.19
Temperature correction for Probe=-0.50
System Liquid Low Level=500 (0%)
System Liquid High Level=780 (100%)
Waste Low Level=724 (0%)
Waste High Level=984 (100%)
Sensitivity of level detection=70
Origin X=23
Origin Y=20
Origin Z=445
Tray Reference X=1349
Tray Reference Y=335
Washing station X=1349
Washing station Y=22
Washing station Z=275
Reactions Rotor X=2887
Reactions Rotor Y=678
Reactions Rotor Z=415
Rotor Distance between the dispensation point and the optic system=1427
Rotor Position correction regard to the dispensation point=7
Rotor Position correction regard to the optic system=-4
Filters Wheel correction=-4
Filters and their Integration Times:
Filter 1=000 Integration Time= 10ms ( 20) Reference Time= 10ms ( 19)
Filter 2=340 Integration Time= 70ms (136) Reference Time= 70ms (136)
Filter 3=405 Integration Time= 14ms ( 28) Reference Time= 14ms ( 27)
Filter 4=505 Integration Time= 15ms ( 29) Reference Time= 15ms ( 29)
Filter 5=535 Integration Time= 16ms ( 31) Reference Time= 16ms ( 31)
Filter 6=560 Integration Time= 13ms ( 26) Reference Time= 13ms ( 25)
Filter 7=600 Integration Time= 19ms ( 37) Reference Time= 19ms ( 37)
Filter 8=635 Integration Time= 14ms ( 28) Reference Time= 14ms ( 27)
Filter 9=670 Integration Time= 25ms ( 48) Reference Time= 25ms ( 48)
Filter 10=000 Integration Time= 10ms ( 20) Reference Time= 10ms ( 19)
Zmax Reference=194
- Pediatric Offset=0
- 13mm Offset=0
- 15mm Offset=0
- Reagent Offset=100
- Central Reagent Offset=0
A25 Mechanical History
- X axis: 1207 Steps
- Y axis: 1157 Steps
- Z axis: 1449 Steps