4. SERVICE PROGRAM
The service program is used for the adjustment, checking and maintenance of the different components of the
analyzer. It is not supplied with the instrument, it is supplied to authorised technical services only. The personal of
the Technical Service must install it on the user’s computer in order to carry out the service requirements. Once
the tasks have finalised, the program must be uninstalled. To install the program, follow the instructions on the
installation CD ROM called Service. The original password for using this program is A25. The password can be
changed from the service program itself. If the service personnel forget the password, the original password can be
reinstalled by deleting the hidden file code.a25 from the application directory and relaunching the program. Once
the password has been introduced, the analyzer serial number is given and the name of the operator is requested
(by default Operator1). Press the Accept button and the main program appears. The different functions of the
service program are classified in the following categories:
- Adjustments: These make it possible to make different parameter adjustments required for the correct
functioning of the analyzer.
- Tests: Tests for checking the functionality of the analyzer.
- Utilities: Different technical utilities, such as, for example, washing or priming the dispensing system or
changing an optical filter.
- Registers:This enables the management of past adjustments, tests, incidences, repairs and maintenance of
the instrument.
- Monitor:These enable the low level communication with the analyzer to load new versions of the program in the
flash memory of the analyzer (firmware) or to consult the internal parameters of the instrument.
An emergency stop button (STOP on a red background) will be accessible at all times, and when pressed, it
switches off the analyzer and closes the application quickly.
4.1 Initialising the analyser
To initialise the analyser in service mode, first launch the A25 Service application. The program first of all requests
a user or technician ID to be used in the program. Depending on the type of user identified, access to the different
parts of the program will be allowed or denied. The following screen appears:
For full access, enter the following codes:
Name (login): SAT
Password: A25

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the biosystems A25 and is the answer not in the manual?

biosystems A25 Specifications

General IconGeneral
Brandbiosystems
ModelA25
CategoryMeasuring Instruments
LanguageEnglish