Description Symbol Unit
HCS01.1E
-W0003-
_-02
HCS01.1E
-W0006-
_-02
HCS01.1E
-W0009-
_-02
HCS01.1E
-W0013-
_-02
HCS01.1E
-W0018-
_-02
Three-phase mains voltage at IT
mains
1)
U
LN
V 110...230
Three-phase mains voltage at
Corner-grounded-Delta mains
2)
U
LN
V 110...230
Tolerance rated input voltage U
LN
% ± 10
Minimum short circuit power of the
mains for failure-free operation
S
k_min
MVA 0.02 0.03 0.05 0.1 0.2
Minimum inductance of mains
supply (mains phase inductance)
3)
L
min
µH 40
Assigned type of mains choke -
Inrush current
I
L_trans_max
_on
A See figure
Maximum allowed ON-OFF cycles
per minute
4)
1
Mains input continuous current at
U
LN_nenn
and P
DC_cont
(single-
phase, without mains choke)
5)
I
LN
A 1.80 2.80 5.00 8.30 12.80
Mains input continuous current at
U
LN_nenn
and P
DC_cont
(three-phase,
without mains choke)
6)
I
LN
A 0.60 1.20 2.30 4.50 9.60
Mains input continuous current at
U
LN_nenn
and P
DC_cont
(single-
phase, with mains choke)
7)
I
LN
A -
Mains input continuous current at
U
LN_nenn
and P
DC_cont
(three-phase,
with mains choke)
8)
I
LN
A -
Nominal current AC1 for mains
contactor at nom. data
ILN
Mains fuse according to
EN 60204-1 (single-phase, with‐
out mains choke)
A 4;gG 6;gG 10;gG 16;gG
Mains fuse according to
EN 60204-1 (three-phase, without
mains choke)
A 2;gG 4;gG 6;gG 16;gG
Mains fuse according to
EN 60204-1 (single-phase, with
mains choke)
A -
Mains fuse according to
EN 60204-1 (three-phase, with
mains choke)
A -
Last modification: 2012-06-28
Bosch Rexroth AG DOK-INDRV*-HCS01******-PR05-EN-P234/341
Rexroth IndraDrive CsDrive Systems with HCS01
Technical data of the components