Description Symbol Unit
HCS01.1E
-W0003-
_-02
HCS01.1E
-W0006-
_-02
HCS01.1E
-W0009-
_-02
HCS01.1E
-W0013-
_-02
HCS01.1E
-W0018-
_-02
Output frequency range when
f
s
= 4 kHz
f
out_4k
Hz 0...400
Output frequency range when
f
s
= 8 kHz
f
out_8k
Hz 0...800
Output frequency range when
f
s
= 12 kHz
f
out_12k
Hz 0...1200
Output frequency range when
f
s
= 16 kHz
f
out_16k
Hz 0...1600
Output frequency threshold for de‐
tecting motor standstill
4)
f
out_still
Hz 4
Maximum output current when
f
s
= 4 kHz
I
out_max4
A 3.3 6.0 9.0 13.0 18.0
Maximum output current when
f
s
= 8 kHz
I
out_max8
A 3.3 6.0 9.0 13.0 18.0
Maximum output current when
f
s
= 12 kHz
I
out_max12
A 3.3 6.0 9.0 13.0 18.0
Maximum output current when
f
s
= 16 kHz
I
out_max16
A 3.3 6.0 9.0 13.0 18.0
Continuous output current when
f
s
= 4 kHz
I
out_cont4
A 1.4 2.4 3.0 4.4 7.6
Continuous output current when
f
s
= 8 kHz
I
out_cont8
A 1.0 1.8 2.6 4.2 7.6
Continuous output current when
f
s
= 12 kHz
5)
I
out_cont12
A 0.6 1.2 1.7 2.7 7.6
Continuous output current when
f
s
= 16 kHz
6)
I
out_cont16
A 0.5 0.8 1.1 1.9 7.6
Continuous output current when
f
s
= 4 kHz; output frequency
f
out
< f
out_still
I
out_cont0Hz
_4
A 1.1 2.1 3.0 4.4 7.6
Continuous output current when
f
s
= 8 kHz; output frequency
f
out
< f
out_still
I
out_cont0Hz
_8
A 0.9 1.6 2.3 3.1 6.0
Continuous output current when
f
s
= 12 kHz; output frequency
f
out
< f
out_still
7)
I
out_cont0Hz
_12
A 0.5 1.0 1.4 2.0 5.0
Last modification: 2015-06-12
Bosch Rexroth AG DOK-INDRV*-HCS01******-PR05-EN-P244/341
Rexroth IndraDrive CsDrive Systems with HCS01
Technical data of the components