Mounting
● Before mounting the snap-on ferrite, store it for at least 1 hour at a tem‐
perature of 15 … 25 °C.
● When mounting the snap-on ferrite, avoid putting it under mechanical
stress. The housing or the ferrite core might brake.
● Do not mount the snap-on ferrite in the immediate vicinity of strong heat
sources. The maximum allowed ambient temperature of the snap-on fer‐
rite is 105 °C.
● Fix the snap-on ferrite within the control cabinet to the cable jacket of
the connection line of the braking resistor (see picture). The snap-on fer‐
rite is designed for cable diameters of 6.5 … 7 mm.
Fig. 8-40: Snap-on ferrite at connection line of external braking resistor
Bosch Rexroth AG DOK-INDRV*-HCS01******-PR05-EN-P288/341
Rexroth IndraDrive CsDrive Systems with HCS01
Cables, accessories, additional components