Loading...
40-77
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-08
Chapter 40 Configuring IP Unicast Routing
Configuring Multi-VRF CE
Figure 40-6 shows a configuration using Catalyst 3750-E or 3560-E switches as multiple virtual CEs.
This scenario is suited for customers who have low bandwidth requirements for their VPN service, for
e
xample, small companies. In this case, multi-VRF CE support is required in the Catalyst 3750-E
or 3560-E switches. Because multi-VRF CE is a Layer 3 feature, each interface in a VRF must be a
La
yer 3 interface.
Figure 40-6 Switches Acting as Multiple Virtual CEs
When the CE switch receives a command to add a Layer 3 interface to a VRF, it sets up the appropriate
mapping between the VLAN ID and the policy label (PL) in multi-VRF-CE-related data structures and
adds the VLAN ID and PL to the VLAN database.
When multi-VRF CE is configured, the Layer 3 forwarding table is conceptually partitioned into two
sec
tions:
The multi-VRF CE routing section contains the routes from different VPNs.
The global routing section contains routes to non-VPN networks, such as the Internet.
VLAN IDs from different VRFs are mapped into different policy labels, which are used to distinguish
t
he VRFs during processing. For each new VPN route learned, the Layer 3 setup function retrieves the
policy label by using the VLAN ID of the ingress port and inserts the policy label and new route to the
multi-VRF CE routing section. If the packet is received from a routed port, the port internal VLAN ID
number is used; if the packet is received from an SVI, the VLAN number is used.
This is the packet-forwarding process in a multi-VRF-CE-enabled network:
When the switch receives a packet from a VPN, the switch looks up the routing table based on the
input policy label number. When a route is found, the switch forwards the packet to the PE.
When the ingress PE receives a packet from the CE, it performs a VRF lookup. When a route is
found, the router adds a corresponding MPLS label to the packet and sends it to the MPLS network.
When an egress PE receives a packet from the network, it strips the label and uses the label to
identify the correct VPN routing table. Then it performs the normal route lookup. When a route is
found, it forwards the packet to the correct adjacency.
When a CE receives a packet from an egress PE, it uses the input policy label to look up the correct
VPN routing table. If a route is found, it forwards the packet within the VPN.
VPN 1
VPN 2
VPN 1
VPN 2
CE2PE1 PE2
Service
provider
CE1
CE = Customer-edge device
PE = Provider-edge device
101385