NAS Maintenance
Powe r Outage or Ab no rm al Shutdo wn
Cisco Small Business NSS 322, NSS 324, and NSS 326 Smart Storage Administration Guide 181
5
Power Outage or Abnormal Shutdown
In case of a power outage or improper shu tdown of the NAS, it will resume to the
state before it is shut down .
NOTE
Oth er pow er outage options are available from the
External Device >
UPS Settings
window.
If your NAS does not function properly after restart, do the following:
STEP 1
If the system configuration is lost, configure the system again.
STEP 2
In the event of abnormal operation of the NAS, co ntact customer service for
technical support.
System Software Abnormal Operation
If the system software does not operate properly, the NAS automatically restarts
t o r e su me normal o pe r at ion. I f y o u f ind t h at th e s yst e m rest art s co ntinu o u sly, i t may
fail to resu me nor mal oper ation. In this cas e, con tact tech nica l support.
System Temperature Protection
The sys tem shuts dow n automatica lly for hard wa re protection if any of the
follow ing cr iter ia is met :
The system temperature exceeds 70°C (158°F)
The CPU temperature exceeds 85°C (185°F)
The hard drive temperature exceeds 65°C (149°F)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco NSS 322 and is the answer not in the manual?

Cisco NSS 322 Specifications

General IconGeneral
BrandCisco
ModelNSS 322
CategoryStorage
LanguageEnglish

Related product manuals