EasyManua.ls Logo

Cloos QINEO NexT - Compensation of the External Welding Circuit; Config - General (2); Gas Flow - Min;Max; TIG - Pot Setting Range - Min;Max

Cloos QINEO NexT
234 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
136
Configuration menu
The start job must be in the first position of any tens position, for example:
Storage space 11, 21, 31 … 801. As soon as an empty storage space is
available between an active job and the next job, this is detected and the
system will jump back to the job with the position xx1.
Example:
Active job: 44, next job: 48, job continuation to storage space: 41.
5.4 Config - General (2)
5.4.1 Wire speed in
Herewith you select the display of the dimension for the wire feed speed.
5.4.2 V-display shows
Select here whether the display shows the process voltage (terminal
voltage minus values of the external welding current circuit = calculated
voltage at the workpiece) or the terminal voltage (voltage at the welding
power source).
To validate the welding power source, the terminal voltage must be set
here. Otherwise the voltage display will be incorrect.
5.4.3 Gas flow - min/max
Herewith you determine the minimum and maximum limit values for the
"Gas-Yes-Signal" in litres.
5.4.4 TIG - pot setting range - min/max
In this menu item you determine the minimum and maximum value that
a welding torch equipped with a potentiometer can achieve in the TIG
welding process.
5.5 Compensation of the external welding circuit
The voltage values depend on the size of the external circuit. When chang-
ing the external circuit, you have to determine the compensation again!
The compensation is made via an automated measurement.
Before starting the measurement, make sure that either:
there is no welding wire in the torch
or
the welding wire is pulled off the torch so that the wire does not stick
out of the current tip.
INFO!
ATTENTION!