Using Setup mode procedures
HF SSB transceiver reference manual 4-3
List of Setup mode procedures
Procedures labelled standard are available in all HF SSB
series transceivers.
Procedure Page Setup
code
Description
ALE alphanumeric
address
5-2 2434 Sets the alphanumeric address of your
transceiver.
ALE option reset 5-4 2432 Resets 9 of the 17 ALE option settings 0–16
to their factory values.
ALE option
settings
5-6 2431 Changes how the ALE controller works.
ALE sounding
interval
5-13 2433 Changes the ALE sounding time interval.
Beep loudness
(standard)
5-15 33 Changes the volume of beeps made by the
transceiver.
Call preamble
length
5-17 242 Sets the length of the preamble transmitted at
the start of a selective call.
Call privacy on/off 5-19 2443 Limits the stations that can receive your
transmissions of GPS, page and status call
information.
Clock calibration
(standard)
5-21 412 Calibrates the transceiver clock against an
external standard.
Clock setting
(standard)
5-23 411 Sets the time and date of the transceiver
clock.
Using Setup mode procedures
HF SSB transceiver reference manual 4-3
List of Setup mode procedures
Procedures labelled standard are available in all HF SSB
series transceivers.
Procedure Page Setup
code
Description
ALE alphanumeric
address
5-2 2434 Sets the alphanumeric address of your
transceiver.
ALE option reset 5-4 2432 Resets 9 of the 17 ALE option settings 0–16
to their factory values.
ALE option
settings
5-6 2431 Changes how the ALE controller works.
ALE sounding
interval
5-13 2433 Changes the ALE sounding time interval.
Beep loudness
(standard)
5-15 33 Changes the volume of beeps made by the
transceiver.
Call preamble
length
5-17 242 Sets the length of the preamble transmitted at
the start of a selective call.
Call privacy on/off 5-19 2443 Limits the stations that can receive your
transmissions of GPS, page and status call
information.
Clock calibration
(standard)
5-21 412 Calibrates the transceiver clock against an
external standard.
Clock setting
(standard)
5-23 411 Sets the time and date of the transceiver
clock.