EasyManuals Logo

Curtiss-Wright R-NET User Manual

Curtiss-Wright R-NET
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #159 background imageLoading...
Page #159 background image
Curtiss-Wright | PG Drives Technology
SK77981-14
159 | R-net Technical Manual | Chapter 8 ISM-8
4 CONNECTIONS
4.1 R-NET REBUS
WARNING:
The Bus connections can only be used to connect the ISM-8 to an R-net Control System using Curtiss-Wright supplied R-net
Communication Cables. Curtiss-Wright accept no liability for any losses of any kind if an incorrect cable is used.
4.2 INHIBITS
The ISM-8 contains Inhibit 18 to 33 connections. These connections can be used to limit speed, inhibit drive and /or inhibit
actuator channels. Refer to Section 5 Programming for full details.
Signals to the Inhibit connector can be passive, i.e. A resistor varying from 0 to 10k, or active, i.e. a voltage source varying
from 0V to 3.3V.