76 | R-net Technical Manual | Chapter 3 Programming
Sets the deceleration rate of the wheelchair in the forward direction when the speed setting is at minimum (just 1 bar
illuminated).
Programmable range is 0 to Maximum Forward Deceleration in steps of 1%.
NOTE:
It is not possible to set the value of Minimum Forward Deceleration higher than the value of Max. Forward Deceleration.
6.11 MAXIMUM REVERSE ACCELERATION - (REV ACCEL MAX)
Sets the acceleration rate of the wheelchair in the reverse direction when the speed setting is at maximum (all 5 bars
illuminated).
Programmable range is 0 to 100% in steps of 1%.
6.12 MINIMUM REVERSE ACCELERATION - (REV ACCEL MIN)
Sets the acceleration rate of the wheelchair in the reverse direction when the speed setting is at minimum (just 1 bar
illuminated).
Programmable range is 0 to Maximum Reverse Acceleration in steps of 1%.
NOTE:
It is not possible to set the value of Minimum Reverse Acceleration higher than the value of Max. Reverse Acceleration.
6.13 MAXIMUM REVERSE DECELERATION - (REV DECEL MAX)
Sets the deceleration rate of the wheelchair in the reverse direction when the speed setting is at maximum (all 5 bars
illuminated).
Programmable range is 0 to 100% in steps of 1%.
6.14 MINIMUM REVERSE DECELERATION - (REV DECEL MIN)
Sets the deceleration rate of the wheelchair in the reverse direction when the speed setting is at minimum (just 1 bar
illuminated).
Programmable range is 0 to Maximum Reverse Deceleration in steps of 1%.
NOTE:
It is not possible to set the value of Minimum Reverse Deceleration higher than the value of Max. Reverse Deceleration.
6.15 MAXIMUM TURN ACCELERATION - (TURN ACCEL MAX)
Sets the acceleration rate of the wheelchair into a turn when the speed setting is at maximum (all 5 bars illuminated).
Programmable range is 0 to 100% in steps of 1%.