178 | R-net Technical Manual | Chapter 9 Lighting Module (LM)
5.2 LIGHT POWER
This should be programmed to match the total power of all the bulbs in the lighting circuits.
The programmable range is 1W to 42W in steps of 1W.
5.3 INDICATOR POWER
This should be programmed to match half the total power of all bulbs in the turn-indicators circuits. Note: the value should
correspond to half because the turn indicators always flash at a duty cycle of 50%
The programmable ranges is 1W to 42W in steps of 1W.
5.4 INDICATOR FAULT POWER
This sets the power threshold for single indicator bulb failure detection.
NOTE:
TÜV Germany requires that 2 x 21W lamps per side are used for the turn indicators.
With Indicator Fault Detection set to Yes, If the total power drawn from the indicator output is less than the value programmed,
the indicator shall be considered to be faulty. The parameter Indicator Fault Power is programmable from 0.5W to 50W in steps
of 0.25W. For example, if 2 x 21W bulbs are fitted to each channel it is recommended to set this power threshold at
approximately 30W.