Page #38 background imageLoading...
Page #38 background image
Curtiss-Wright | PG Drives Technology
SK77981-14
38 | R-net Technical Manual | Chapter 2 - Installation
Wright accepts no liability for losses of any kind if the drive or stability characteristics of the chair are altered without prior
notification and discussion with Curtiss-Wright.
NOTE:
It is possible for wheelchair manufacturers to limit the values of speeds and accelerations that can be programmed in the
field. This facility ensures a safe-operating envelope for the wheelchair can be maintained.
1.3 SOFT-STOP
The R-net has a programmable value called Soft Stop Rate that sets the emergency stopping distance. You must ensure that the
emergency stopping distance is within the distance specified for the country in which the wheelchair will be used. TÜV Product
Services (Germany) specify the distance to be as stated in EN12184.
1.4 OTHER INFORMATION
You must provide a diagram in the wheelchair user handbook showing the user controls and the main features of the control
system.
In addition, you should include a brief specification of operating supply voltage range and operating temperature range.
2 IMMOBILIZING THE WHEELCHAIR
2.1 PREVENTION OF UNAUTHORIZED USE
TÜV requires that the wheelchair must have a means of preventing unauthorized use. This can be implemented as detailed in
Chapter 1 section 5.4.
2.2 CHARGER INTERLOCK
ISO 7176-14 requires you to provide a means of preventing the use of the wheelchair while the batteries are being charged. The
charger socket and on-board charger connection fitted to Curtiss-Wright R-net control systems include an inhibit facility. Refer
to section 6.5.
Contact Curtiss-Wright if you need advice.
WARNING:
The chair manufacturer is responsible for providing a means of preventing the use of the wheelchair while the batteries are
being charged. Curtiss-Wright accepts no liability for losses of any kind arising from failure to comply with this condition.
2.3 POWER DOWN
The control system can be programmed to power down if the joystick is not operated over a set period of time. Refer to
Chapter 3 for programming details.
To restart, switch the control system on.