xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Web UI Reference Guide
211
Figure 7-46 ACL Flow meter Configuration window
The fields that can be configured are described below:
Parameter Description
Profile ID (1-14)
Enter the Profile ID for the flow meter.
Profile Name
Enter the Profile Name for the flow meter.
Access ID (1-
128)
Enter the Access ID for the flow meter.
Mode
RateSpecify the rate for single rate two color mode.
RateSpecify the committed bandwidth in Kbps for the flow.
Burst SizeSpecify the burst size for the single rate two color mode. The unit is in
kilobyte.
Rate ExceededSpecify the action for packets that exceed the committed rate in
single rate two color mode. The action can be specified as one of the following:
o Drop PacketDrop the overload packets immediately.
o Remark DSCPMark the packet with a specified DSCP.
trTCMSpecify the “two-rate three-color mode.”
CIRSpecify the Committed information Rate. The unit is Kbps. CIR should always
be equal or less than PIR.
PIRSpecify the Peak information Rate. The unit is Kbps. PIR should always be
equal to or greater than CIR.
CBSSpecify the Committed Burst Size. The unit is in kilobyte.
PBSSpecify the Peak Burst Size. The unit is in kilobyte.
srTCMSpecify the “single-rate three-color mode”.
CIRSpecify the Committed Information Rate. The unit is in kilobyte.
CBSSpecify the Committed Burst Size. The unit is in kilobyte.

Table of Contents