xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Web UI Reference Guide
23
Class 1 : 4000mW
Class 2 : 7000mW
Class 3 : 15400mW
User define: 30000mW (15400~30000 only applies to ports 1 - 8)
As well as these four pre-defined settings, users can directly specify any value ranging
from 1000mW to 30000mW on DES-3528P/DES-3552P ports 1 to 8 and 1000mW -
15400mW on DES-3528P ports 9 to 24/DES-3552P ports 9 to 48.
NOTE: DES-3528P/DES-3552P ports 1 to 8 can support PoE up to 30W by configuring
the PoE port user define value, also all ports can support 802.3af (1000 - 15400mW).
Click Apply to implement changes made. The port status of all PoE configured ports is displayed in the table in the
bottom half of the screen shown above.
Click the Refresh button to update the display section of this page.
Serial Port Settings
This window allows the user to adjust the Baud Rate and the Auto Logout values.
To view the following window, click System Configuration > Serial Port Settings, as shown below:
Figure 2-16 Serial Port Settings window
The fields that can be configured are described below:
Parameter Description
Baud Rate
Specify the baud rate for the serial port on the Switch. There are four possible baud rates to
choose from, 9600, 19200, 38400 and 115200. For a connection to the Switch using the
console port, the baud rate must be set to 115200, which is the default setting.
Auto Logout
Select the logout time used for the console interface. This automatically logs the user out
after an idle period of time, as defined. Choose from the following options: 2, 5, 10, 15
minutes or Never. The default setting is 10 minutes.
Data Bits
Display the data bits used for the serial port connection.
Parity Bits
Display the parity bits used for the serial port connection.
Stop Bits
Display the stop bits used for the serial port connection.
Click the Apply button to implement changes made.
System Log configuration
System Log Settings
The Switch allows users to choose a method for which to save the switch log to the flash memory of the Switch.