14
Outline of D-BACS System
4. List of Control System Equipment and Functions
Control Monitoring Other controls
Type Number of
controllable indoor
units for each
controller
ON/OFF
Temperature setting
Cool/heat changeover
Remote control acceptance/rejection
Air flow rate setting
Air flow direction setting
Forced thermostat OFF
Weekly schedule control
ON/OFF status
Error
Malfunction code
Indoor temperature
Filter sign
Power estimation
Status output with thermostat ON
Fan status output
Without remote controller
Zone control
Forced OFF by external contact
ON/OFF by external contact
Demand control
Low operating noise control
intelligent Manager
III
1024 groups
zzzzzz— zzzzzzz— zzz
z
*1
zz ×
LONWORKS
®
64 groups
zzzzzzz— zzzzz— z — z — z ———
BACnet
®
256 groups
zzzzzzz— zzzzz
z
*2
zzz × z ×××
Parallel interface 16 groups
zz× z ××××zz× zz×××××zz××
intelligent Touch
Controller
128 groups
*3
zzzzzz× zzzzzz
z
*2
××zzz×××
Central remote
controller
64 groups
zzzz
▲▲
××zzz× z ×××zzz×××
Unified ON/OFF
controller
16 groups
z ××z ××××zz————————z ———
Schedule timer 128 groups
z ××z ×××z ××××××××××××××
Wired Remote
Controller
—
zzz× zz××zzzzz×××××××××
Wireless Remote
Controller
—
zzz× zz××zzzzz×××××××××
Simplified Remote
Controller
—
zzz× z —× ×zzzz××××××××××
Remote Controller
for Hotel Use
—
zzz× z —× ×zzzz××××××××××
Wired Remote
Controller with Weekly
Schedule Timer
—
zzz× zz× zzzzzz ×××××××××
Interface adaptor
for SkyAir series
—
zzzz
▲
*5
▲
*5
▲
*4
×
▲
*5
▲
*5
z
▲
*6
z ×
▲
*7
▲
*4
z —××××
Interface adaptor
for DIII-NET(RA)
—
zz× z ××—×zzzz×××××z ×××—
Wiring adaptor for
other air conditioners
—
z ××××××××z ××××××———×——
Di, Dio unit —
z
*8
×××××××zz××××××××××××
Unification adaptor for
computerized control
—
————————zz—————————z ——
Wiring adaptor for
electrical appendices (2)
16 units
zz× z ××××zz————————zzz—
Wiring adaptor for
electrical appendices (1)
64 groups
zz× z ××z × zz————————zzz—
Adaptor for wiring 1 unit
——————————————zz——————
External control adaptor
for outdoor unit
10 units
(Outdoor unit)
××z ×××××————————————zz
z : Possible *1 "Emergency Stop" function is possible.
*2 Optional accessory is required.
*3 Possible when DIII-NET PLUS adaptor are used in combination. If not, 64 groups.
*4 OFF when interlocked with BACnet
®
.
*5 Possible from central control equipment (i.e., intelligent Touch Controller,
LONWORKS
®
, BACnet
®
, or Unified ON/OFF Controller)
*6 Possible with parallel interface.
*7 Possible with BACnet
®
or LONWORKS
®
.
*8 Dio unit only.
▲ : Possible under condition
× : Impossible
— : Outside the application