Enter/Exit Programming Mode
Product Reference Guide
99
Code 39 Decoding Levels
This setting has no effect for AR models.
Decoding Levels are used to configure
a bar code symbology decoder to be
very aggressive to very conservative depending on a particular customer’s
needs.
()
Code 39 Decoding Level = Disabled
$CC3LO03(CR)
Code 39 Decoding Level = 1
$CC3LO02(CR)
Code 39 Decoding Level = 2
$CC3LO03(CR)
Code 39 Decoding Level = 3
DEFAULT
$CC3LO02(CR)
Code 39 Decoding Level = 4
$CC3LO03(CR)
Code 39 Decoding Level = 5
Code 39 Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the Code 39 symbology.
Variable Length.
For variable length decoding, a minimum and maximum
length may be set.
Fixed Length.
For fixed length decoding, two different lengths may be set.
DEFAULT
Code 39 Length Control = Variable Length
$CC3LC01(CR)
Code 39 Length Control = Fixed Length