CODE 93
The following options apply to the Code 93 symbology.
Code 93 Enable/Disable
Enables/Disables ability of reader to decode Code 93 labels.
DEFAULT
$CC9EN00(CR)
Code 93 = Disable
$CC9EN01(CR)
Code 93 = Enable
Code 93 Check Character Calculation
This setting has no effect for AR models.
Enables/disables calculation and verification of an optional Code 93 check
ch
aracter.
$CC9CC00(CR)
Code 93 Check Character Calculation = Disable
$CC9CC01(CR)
Code 93 Check Character Calculation = Enable Check C
$CC9CC02(CR)
Code 93 Check Character Calculation = Enable Check K
$CC9CC03(CR)
Code 93 Check Character Calculation =
Enable Check C and K