EasyManuals Logo

Datalogic PD9330 User Manual

Datalogic PD9330
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
Enter/Exit Programming Mode
34
PowerScan™ PD9330/PBT9300/PM9300
ACK NAK Error Handling
This feature specifies the method the reader uses to handle receive errors
detected while waiting for an ACK character from the host.
DEFAULT
$CR2EH0
ACK NAK Error Handling = Ignore Errors Detected
$CR2EH0
ACK NAK Error Handling = Process Error as Valid ACK Char-
acter
$CR2EH0
ACK NAK Error Handling = Process Error as
Valid NAK Character
Indicate Transmission Failure
This option enables/disables the reader’s ability to sound an error beep to
indicate a transmission failure while in ACK/NAK mode
$CR2TF00(CR)
Indicate Transmission Failure = Disable Indication
$CR2TF01(CR)
Indicate Transmission Failure = Enable Indication
DEFAULT
.

Table of Contents