Enter/Exit Programming Mode
134
PowerScan™ PD9330/PBT9300/PM9300
Standard 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for Standard 2 of 5 Length
Control. Length 1 is the minimum label length if in Variable Length Mode, or
the first fixed length if in Fixed Length Mode. Length includes t
he bar code’s
check and data characters. The length can be
set from 1 to 50 characters.
Table 10 provides some examples for setting Length 1. See page 266 if you
want detailed instructions on setting this feature.
Table 10. Standard 2 of 5 Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Character 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CS2L1
Select Standard 2 of 5 Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar
code above, then the bar code at left followed by dig-
its from the Alphanumeric characters in Appendix D,
K
eypad representing your desired character(s). End
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
an
d not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
08 = Length 1 is 8 Characters

Table of Contents

Other manuals for Datalogic PD9330

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PD9330 and is the answer not in the manual?

Datalogic PD9330 Specifications

General IconGeneral
BrandDatalogic
ModelPD9330
CategoryBarcode Reader
LanguageEnglish

Related product manuals