EasyManuals Logo

Datalogic PD9330 User Manual

Datalogic PD9330
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
Enter/Exit Programming Mode
88
PowerScan™ PD9330/PBT9300/PM9300
EAN 8 to EAN 13
Enable this option to expand EAN 8/JAN 8 labels to EAN 13/Jan 13.
DEFAULT
Expand EAN 8 to EAN 13 = Disable
Expand EAN 8 to EAN 13 = Enable
EAN 8 Minimum Reads
This setting has no effect for AR models.
This feature specifies the minimum number of consecutive times an EAN 8
(Jan
8) label must be decoded before it is accepted as good read.
DEFAULT
EAN 8 Minimum Reads = 1
EAN 8 Minimum Reads = 2
EAN 8 Minimum Reads = 3
EAN 8 Minimum Reads = 4

Table of Contents

Other manuals for Datalogic PD9330

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PD9330 and is the answer not in the manual?

Datalogic PD9330 Specifications

General IconGeneral
BrandDatalogic
ModelPD9330
CategoryBarcode Reader
LanguageEnglish

Related product manuals