Enter/Exit Programming Mode
162
PowerScan™ PD9330/PBT9300/PM9300
GS1 DataBar™ Expanded Minimum Reads
This setting has no effect for AR models.
This feature specifies the minimum number of consecutive times a GS1
DataBar Exp
anded label must be decoded before it is accepted as good read.
DEFAULT
GS1 DataBar Expanded Minimum Reads = 1
GS1 DataBar Expanded Minimum Reads = 2
GS1 DataBar Expanded Minimum Reads = 3
GS1 DataBar Expanded Minimum Reads = 4
GS1 DataBar™ Expanded Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the GS1 DataBar™ Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
DEFAULT
$
GS1 DataBar™ Expanded Length Control =
Variable Length
GS1 DataBar™ Expanded Length Control = Fixed Length