Wireless Features
Product Reference Guide
279
Wireless Features
Automatic Configuration Update
When this feature is enabled, the base station and reader will keep their
configurations synchronized. If a reader's configuration is altered by reading
programming labels, this change is automatically transferred and updated in
a linked base station. Likewise, if the base station's configuration is changed
using Aladdin or by host commands, then the reader's configuration will
automatically be updated if this feature is enabled.
RF Address Stamping
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label
data and radio address when address stamping is enabled.
This feature only applies if
"Source Radio Address Transmis-
sion"
on page 206 is enabled.
Follow these instructions to select the delimiter character:
1. Determine the desired character, then find its hexadecimal equivalent
on
the ASCII Chart on the inside back cover. A setting of 00 specifies no
delimiter character.
2. Go to page 207 and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
3. Scan the bar code: SET SOURCE RADIO ADDRESS DELIMITER CHARAC-
TER.
4. Scan the appropriate two digits from the keypad in Appendix D, Key-
pad, that represent the hexadec
imal characters which were determined
in the steps above. You will hear a two-beep indication after the last
ch
aracter.
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
Table 45. Source Radio Address Delimiter Character Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
No delimiter
character
, (comma) - (dash) / (slash)
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘2’ and ‘C ‘2’ and ‘D’ ‘2’ AND ‘F’
5 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Other manuals for Datalogic PD9330

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PD9330 and is the answer not in the manual?

Datalogic PD9330 Specifications

General IconGeneral
BrandDatalogic
ModelPD9330
CategoryBarcode Reader
LanguageEnglish

Related product manuals