Enter/Exit Programming Mode
Product Reference Guide
115
INTERLEAVED 2 OF 5 (I 2 OF 5)
This setting has no effect for AR models.
The following options apply to the I 2 of 5 symbology.
CAUTION
When reading this symbology, the settings for I 2 of 5 Length Control AND I 2
of 5 Check Character Calculation MUST be enabled to increase decoding
safety.
I 2 of 5 Enable/Disable
When disabled, the reader will not read I 2 of 5 bar codes.
DEFAULT
$
I 2 of 5 = Disable
$CI EN (CR)
I 2 of 5 = Enable
I 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional I 2
of 5 check character. Combinations of these settings are possible via the
Aladdin configuration utility, or contact Technical Support.
DEFAULT
$
I 2 of 5 Check Character Calculation = Disable
I 2 of 5 Check Character Calculation = Check Standard
(Modulo 10) (no AR)
$()
I 2 of 5 Check Character Calculation = Check German Parcel
$
I 2 of 5 Check Character Calculation = Check DHL (no AR)