Enter/Exit Programming Mode
42
PowerScan™ PD9330/PBT9300/PM9300
Wedge Quiet Interval
Specifies amount of time to look for keyboard activity before scanner breaks
keyboard connection in order to transmit data to host. The selectable range
for this setting is 00 to 990 milliseconds (00-0x63 by 01) in increments of
ten milliseconds.
See page 263 in “References” for detailed information and
examples for setting this feature.
$CKBQI
Set Wedge Quiet Interval
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then
the bar code at left followed by the digits from
the Alphanumeric characters in
Appendix D,
Keypad representing your desired character(s).
End by scanning the ENTER/EXIT bar code
twice.
Make a mistake? Scan the CANCEL bar code to
abor
t and not save the entry string. You can
then start again at the beginning.
~
CANCEL
0A = Quiet Interval is
100 milliseconds
DEFAULT
Intercode Delay
Specifies the delay between labels transmitted to the host for this interface.
The selectable range for this feature is from 0 to 99 seconds.
See page 265 in “References” for detailed information and examples for set-
ting this feature.
$CKBID
Set Intercode Delay
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then
the bar code at left followed by the digits from
the Alphanumeric characters in
Appendix D,
Keypad
representing your desired character(s).
End by scanning the ENTER/EXIT bar code
twice.
Make a mistake? Scan the CANCEL bar code to
abor
t and not save the entry string. You can
then start again at the beginning.
~
CANCEL
00 = No Wedge Intercode Delay
DEFAULT

Table of Contents

Other manuals for Datalogic PD9330

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PD9330 and is the answer not in the manual?

Datalogic PD9330 Specifications

General IconGeneral
BrandDatalogic
ModelPD9330
CategoryBarcode Reader
LanguageEnglish

Related product manuals