EasyManuals Logo

Datalogic PD9330 User Manual

Datalogic PD9330
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
Enter/Exit Programming Mode
70
PowerScan™ PD9330/PBT9300/PM9300
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains
on following a good read. The good read LED on time can be set within a
range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in
100ms increments. A setting of 00 keeps the LED on until the next trigger
pull.
See page 276 in “References” for detailed instructions and examples for set-
ting this feature.
$CLAGL00(CR)
Good Read LED Duration Setting =
Keep LED on until next trigger pull
$CLAGL
Select Good Read LED Duration Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the
ENTER/EXIT bar code twice.
Make a mistake? Scan the CANCEL
bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
003 = Good Read LED
stays on for 300 ms.
Indicators are dimmed during sleep.

Table of Contents

Other manuals for Datalogic PD9330

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PD9330 and is the answer not in the manual?

Datalogic PD9330 Specifications

General IconGeneral
BrandDatalogic
ModelPD9330
CategoryBarcode Reader
LanguageEnglish

Related product manuals