EasyManua.ls Logo

Dell 3250 - Page 155

Dell 3250
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
155
Command Switches Description
-V
Causes the BMC to return a high level version of the system health
status in multi-line verbose format. The BMC returns a string of the
following format:
SYS Health:xx<output termination sequence>
Power: ON, OFF (soft-off or mechanical off), SLEEP (sleep - used
when it cannot distinguish sleep level), S4, S3, S2, S1, Unknown
Temperature:xx<output termination sequence>
Voltage:xx<output termination sequence>
PowerSystem:xx<output termination sequence>
Cooling:xx<output termination sequence>
Drives:xx<output termination sequence>
Security:xx<output termination sequence>
Other:xx<output termination sequence>
Where xx is:
OK: monitored parameters within normal operating ranges
Non-critical: warning: hardware outside normal operating range
Critical: fatal hardware exceeding specified ratings
Non-recoverable: potential damage: system hardware in
jeopardy or damaged
Unspecified fault: fault detected, but severity unspecified
Unknown: status not available/unknown (typically because
system power is OFF)