1.10 - Inputs variables
Inputs variables are data coming from the controller and sent to the PLC.
Name Description ASCII values
Numerical
values or
binary format
Reset
condition
Set condition
General Status
Controller name Controller name Never
CVi3 start
or new
conguration
Tightening unit name Tightening Unit name Never
CVi3 start
or new
conguration
CVI3 outputs State of the 8 controller outputs
"Identier %1
...
Identier %4"
Identier #1 stored in result. Tight start Result received
User info code
"Info, error or warning" value
displayed
Error, warning
or info
displayed.
"List of error
and
warning
empty."
Constant
Used to set a constant read by the
PLC.
Keep alive value ack.
Mirror of "Keep Alive" value in PLC
output.
Controller
start
New value in
Keep Alive
Value
User Variable 1 ack.
Mirror of User Variable 1 in PLC
output
Controller
start
New value in
User Variable 1
User variable 2 ack.
Mirror of User Variable 2 in PLC
output
Controller
start
New value in
User Variable 2
Identier echo Last accepted identier
Controller
start
New value in
User Variable 2
Tool Status
Tool model
Tool model connected (e.g. EAD50-
900)
- -
Tool
disconnection
Tool connection
Tool serial number Tool serial number - -
Tool
disconnection
Tool connection
Tool max torque Tool maximum torque in TU units - -
Tool
disconnection
Tool connection
Tool max speed Tool maximum speed in rpm - -
Tool
disconnection
Tool connection
Spindle comment Comment written in tool memory. - -
Tool
disconnection
Tool connection
Tool calibration value
1
Calibration value for tool sensor 1
- -
Tool
disconnection
Tool connection
Tool calibration value
2
Calibration value for tool sensor 2
- -
Tool
disconnection
Tool connection