Serial port Configure PPP dial-in mode
Digi Connect IT® 4 User Guide
235
where value is one of:
n none
n rts/cts
n xon/xoff
8. Set the amount of time that the active session can be idle before the session is disconnected:
(config)> serial port1 idle_timeout value
(config)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the format
number{w|d|h|m|s}.
For example, to set idle_timeout to ten minutes, enter either 10m or 600s:
(config)> serial port1 idle_timeout 600s
(config)>
9. Set the local IP address assigned to this interface:
(config)> serial port1 ppp_dialin local_address IPv4_address
(config)>
10. Set the IP address assigned to the remote peer:
(config)> serial port1 ppp_dialin remote_address IPv4_address
(config)>
11. Set the authentication method used to authenticate the remote peer:
(config)> serial port1 ppp_dialin auth value
(config)>
where value is one of:
n none: No authentication is required.
n auto: Attempt to authenticate using CHAP first, and then PAP.
n chap: Use Challenge Handshake Authentication Protocol (CHAP) to authenticate.
n pap: Use Password Authentication Protocol (PAP) to authenticate.
The default is none.
If auto, chap, or pap are set, set the username and password used to authenticate the remote
peer:
(config)> serial port1 ppp_dialin username username
(config)> serial port1 ppp_dialin password password
(config)>
12. Set the priority of routes associated with this interface. If there are multiple active routes that
match a destination, then the route with the lowest metric will be used.
(config)> serial port1 ppp_dialin metric int
(config)>